HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]
Biomedical waste management ppt
Items/Model
TS50(PLC)
Picture
Principle
Medical Waste Incineration,dual chamber incinerator
Burn Rate
50-100 kg/hour
Control Mode
PLC(Programmable Logic Controller Incinerator)
Combustion Chamber
560L
Internal Dimensions
100x80x70cm
Secondary Chamber
280L
Smoke Filter Chamber
Yes
Feed Mode
Manual
Voltage
220V
Power
0.7Kw
Oil Consumption (kg/hour)
average 16.9
Gas Consumption (m3/hour)
average 20.2
Temperature Monitor
Digital Display
Temperature Protection
Yes
Oil Tank
100L
Feed Door
70x55cm
Chimney
5Meter
Chimney Type
Steel
1st. Chamber Temperature
800℃–1000℃
2nd. Chamber Temperature
1000℃-1200℃
Residency Time
2.0 Sec.
Gross Weight
4500kg
External Dimensions
230x130x155cm
HICLOVER Incinerator/Parts Range |
Main Feature |
Medical Waste Incinerators |
HICLOVER 10-500kgs/Hr.Double Combustion Chambers |
Single Combustion Chamber |
Small, Cheap,10-20kgs/Hr. |
Three Combustion Chambers(Optional) |
3 Chambers for high risk waste |
Pet Cremation Equipment |
For Pet(small/big) Cremation Business |
Animal Incineration Equipment |
For other animal incineration |
Items/Model |
TS100(PLC) |
TS150(PLC) |
TS300(PLC) |
TS500(PLC) |
Burn Rate (Average) |
100 kg/hour |
150 kg/hour |
300 kg/hour |
500 kg/hour |
Control Mode |
PLC Auto. |
PLC Auto. |
PLC Auto. |
PLC Auto. |
Combustion Chamber |
1200L |
1500L |
2000L |
3000L |
Internal Dimensions |
120x100x100cm |
150x100x100cm |
170x120x100cm |
210x120x120cm |
Secondary Chamber |
600L |
750L |
1000L |
1500L |
Smoke Filter Chamber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Feed Mode |
Manual |
Manual |
Manual |
Manual |
Voltage |
220V |
220V |
220V |
220V |
Power |
1.38Kw |
1.69Kw |
2.57Kw |
4.88Kw |
Diesel Oil Consumption (kg/hour) |
Ave.20.4 |
Ave.24.2 |
Ave.33 |
Ave.44 |
Natural Gas Consumption (m3n/hour) |
Ave.24.5 |
Ave.29 |
Ave.39.6 |
Ave.52.8 |
Temperature Monitor |
Yes |
Yes |
Yes |
Yes |
Temperature Protection |
Yes |
Yes |
Yes |
Yes |
Oil Tank |
200L |
300L |
500L |
500L |
Chimney |
10Meter |
10Meter |
14Meter |
14Meter |
Chimney Type |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
1st. Chamber Temperature |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
2nd. Chamber Temperature |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
Residency Time |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
Gross Weight |
6000kg |
8500kg |
11000kg |
16000kg |
External Dimensions |
260x150x180cm |
300x160x190cm |
400x210x300cm |
450x210x300cm |
No |
Description |
Specification |
|
1 |
Type |
Dual Chamber (Primary + Secondary Type Controlled Air Pyro Lytic Biomedical Waste Incinerator with Chimney Arrangement |
yes |
2 |
Incineration Capacity |
>50 Kg. per hour |
Yes, 50-100kgs/hour |
3 |
Duration of Use |
As per operational conditions |
Average 10years |
4 |
Number of Chambers |
02 No.s |
yes |
Number of Burners per Chamber |
01 No.s |
yes |
|
5 |
Total burners per incinerator |
02 No.s |
yes |
6 |
Primary Chamber Operation Temperature |
Max. 900 Degree Celsius |
800-1000 Degree Celsius |
7 |
Secondary Temperature |
Max. 1075 Degree Celsius |
1000-1200 Degree Celsius |
Design Temperature for both chambers |
Max. 1500 Degree Celsius |
1750 Degree Celsius |
|
8 |
Incinerator Efficiency |
98-99 % |
yes |
9 |
Refractory Materials |
High Alumina Refractory |
High Alumina Refractory and firebrick |
10 |
Refractory Type |
Castable type |
yes |
11 |
Ash Removal |
Manual Removal Drawer Tray |
yes |
12 |
Material of Construction of Chamber |
IS 2062 |
Q235, same as IS2062 |
13 |
Type of Burner Used |
Fully Automated Electrically operated burner with Head with photo cell for flame supervision Nozzle and Electrode |
yes |
Connection hoses , Ignitor , Pump Fan & Cabling System |
yes |
||
14 |
Qty. |
01 No. |
|
15 |
Power |
230 / 440 V as per availability at end user |
220-240V |
16 |
Electrical Cabling |
Within battery limits |
Standard 3Meter |
17 |
Refractory |
|
|
18 |
Type |
Castable Type |
yes |
19 |
Anchor Fasteners |
AISI 316 |
Firebrick made,none anchors. S.S fiber 446 |
20 |
Coating on Anchors |
Parafin |
none |
21 |
Alumina Percentage |
40-60 % |
Above 60% |
22 |
Density |
2.1 g/Cubic cm |
3-3.5 g/Cubic cm |
23 |
Service Temperature Max. |
1500 Deg. Celsius |
1750 Deg. Celsius |
|
Insulating Castable |
|
|
24 |
Type |
Castable |
High alumina ceramic fiber Insulation |
25 |
CCS at 110 Degree |
35-45 Kg /Sq. Cm. |
None parameter |
26 |
Grain Size |
5 mm |
None parameter |
27 |
Density |
1.2 gm / cm3 |
220kg/m3 |
28 |
Service Temperature |
1350 Degree C |
1260 Degree C |
|
Control Panel |
|
|
29 |
Degree of Ingress Protection |
IP 55 |
yes |
30 |
Panel MOC |
SS 304 |
yes |
31 |
Panel |
Cabinet with Observation Glass and PLC Programmer |
yes |
32 |
Chimney |
|
|
33 |
MOC |
IS 2062 |
yes |
34 |
Height |
As per requirement |
5 meter |
35 |
Total Space Requirement |
Maximum 5 Mtr. X 5 Mtr. Work |
yes |
2021-02-23