HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]
Effect of biomedical waste on human health
Equipment Technical Specifications |
|
Model |
TS30S |
Picture |
|
Feed Capacity |
78 Liters for primary chamber |
Burning Rate |
Average 30 kgs per hour |
Burning Time per Feed |
0.5 hour |
Voltage |
220V |
Power |
0.5Kw |
Fuel |
Diesel oil |
Burner |
Diesel Oil Burner, 2 sets |
Feed Mode |
Manual |
Fuel consumption (Oil) |
Average 8 Kgs/Hour |
External Dimensions |
90 x 90 x 150cm (main body) |
Internal Dimensions |
Dia.50 x 40cm(Primary Chamber) |
Waste combustion chamber |
78Liters |
Post Combustion Chamber |
50Liters |
Oil Tank Capacity |
100 Liters |
Door Opening |
25 x 25cm |
Chimney |
3.0M |
Gross Weight |
1200kgs |
Chamber Material |
Refractory Concrete |
Max. Heat Value |
80,000Kcal/Hr. |
Operation Technical Specifications |
|
Chamber temperature |
8000C -10000C |
Chamber Anti-Rate |
13500C |
Residency time |
0.5 Sec. |
Burning efficiency |
>98% |
Waste Lower Calorific Power |
3000Kcal |
HICLOVER Incinerator/Parts Range |
Main Feature |
Medical Waste Incinerators |
HICLOVER 10-500kgs/Hr.Double Combustion Chambers |
Single Combustion Chamber |
Small, Cheap,10-20kgs/Hr. |
Three Combustion Chambers(Optional) |
3 Chambers for high risk waste |
Pet Cremation Equipment |
For Pet(small/big) Cremation Business |
Animal Incineration Equipment |
For other animal incineration |
effect of biomedical waste on human health
Items/Model |
TS100(PLC) |
TS150(PLC) |
TS300(PLC) |
TS500(PLC) |
Burn Rate (Average) |
100 kg/hour |
150 kg/hour |
300 kg/hour |
500 kg/hour |
Control Mode |
PLC Auto. |
PLC Auto. |
PLC Auto. |
PLC Auto. |
Combustion Chamber |
1200L |
1500L |
2000L |
3000L |
Internal Dimensions |
120x100x100cm |
150x100x100cm |
170x120x100cm |
210x120x120cm |
Secondary Chamber |
600L |
750L |
1000L |
1500L |
Smoke Filter Chamber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Feed Mode |
Manual |
Manual |
Manual |
Manual |
Voltage |
220V |
220V |
220V |
220V |
Power |
1.38Kw |
1.69Kw |
2.57Kw |
4.88Kw |
Diesel Oil Consumption (kg/hour) |
Ave.20.4 |
Ave.24.2 |
Ave.33 |
Ave.44 |
Natural Gas Consumption (m3n/hour) |
Ave.24.5 |
Ave.29 |
Ave.39.6 |
Ave.52.8 |
Temperature Monitor |
Yes |
Yes |
Yes |
Yes |
Temperature Protection |
Yes |
Yes |
Yes |
Yes |
Oil Tank |
200L |
300L |
500L |
500L |
Chimney |
10Meter |
10Meter |
14Meter |
14Meter |
Chimney Type |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
1st. Chamber Temperature |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
2nd. Chamber Temperature |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
Residency Time |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
Gross Weight |
6000kg |
8500kg |
11000kg |
16000kg |
External Dimensions |
260x150x180cm |
300x160x190cm |
400x210x300cm |