laboratory incinerator

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]

the entire carcass of animals ( cattle , horses ,
Sheep, pigs , etc.) , as well as biologically hazardous waste
Products in the fuel stove .
? Opening Doors – the closure and fixation automated system ,
Which are managed remotely by the operator .
? designed to work in long mode and fast
Action ( Quick Start EP – i)
? Fully mobile – mounted on wheeled chassis
Even during the operation . Incinerators must be provided
As standard equipment a special truck

air retention for at least 2 seconds at a temperature of less than 850C, the combustion
In order to achieve the proper effect.
? must be a two-chamber incinerators, primary and secondary
Fuel stoves
? The waste products to reduce the initial volume
Possible to minimize (approximately 5% sterile ash
Form).

Incinerators should be provided in the fuel tank (diesel )
? The minimum capacity of the animal carcass incinerator
The destruction of 1000 kg / hour. Incinerator capacity is calculated
8MJ/kg- material and 60 % humidity.
? It must be possible to use the incinerator +40
C to – 15 0C laboratory incinerator
Temperature and 5% – 95% – of moisture conditions.
? PLC controller and a built-in temperature panelita complete
Automatic control, a control computer, which is stored
Information on the variation of temperature with respect to time and
Graphic images.
? must have fuel with automatic control and malfunction
Detection system.
?the ability to pre- warm-up , body waste burning on and off
Consistency is independent of the first and secondary chambers.
? ensuring the incinerator with electricity , it
Must be installed on the generator.
? clean the incinerator should be simple tools ,
Without using any additional equipment

[ecwid widgets="productbrowser search categories" default_category_id="CATEGORY_ID" default_product_id="PRODUCT_ID" lang="EN"]