waste incinerator manufacturers from china

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]

Incinerate: medical waste and general waste Capacity to burn waste:
400-500kg/hr
Fuel: Diesel
Fuel Consumption: 10 liters/hr maximum
Incineration temperature: 950-1300 degrees centigrade
Casing: thick (min 5mm) stainless steel casing and fully insulated to
withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz
high-capacity, powerful, European Standard incinerator,ideal for high volume incineration,with integral after-burner for greater efficiency and emissions control.
Waste Type and Burn Rate
Designed specifically for use by poultry farmers,
sheep farm owners,   abbatoirs and for pet
cremation. The incinerator will burn up to 50kg of
waste per hour (up to 150kg burn
Construction
Mild steel welded fabrication consisting of sheet steel
and structural section supports.
Lining
Monolithic high grade refractory concrete with high grade insulation backing.
Burners
Fully automatic, high-efficiency burners with electronic ignition, flame recognition and combustion control devices fitted.
Loading – Ash removal
Manual ash removal from the primary chamber. (Ash doors are available on request).
Exterior finish
Multi-coat high quality, high-temperature aluminium enamel top coat paint, finished in silver.
Control
Fully automatic sequential control provided by internal
waste incinerator manufacturers from china, PLC system providing control of:
1. Secondary chamber pre-heat
2. Burn cycle (variable)
3. Cool down cycle
Fuel Options
Diesel, LPG, Natural or Bio Gas.
Typical Fuel Consumption
Diesel: 8 / 10 litres per hour
Liquid Propane Gas: 6 / 8 litres per hour
Natural Gas: 7 / 9 Nm3 per hour
Electrical supply
240volt 16 amp.
Key Specifications
Chamber Volume 2.38m3:
2.2m (l) x 0.9m(w) x 1.2m(h)
Load Capacity up to 1000kg
Load Method Top.·         Type: Pyrolytic

·         Use: For drugs

·         With Chassis to be Mounted in truck/lorry

·         May have a primary and secondary combustion chamber

·         Must have a dilution chamber

·         Capacity: 100 Kgs per hour

·         Power Source: Diesel or Natural Gas or Liquified Natural Gas

[ecwid widgets="productbrowser search categories" default_category_id="CATEGORY_ID" default_product_id="PRODUCT_ID" lang="EN"]