HICLOVER 10-500kgs/Hr.Double Combustion Chambers

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


TECH SPECS FOR 200KGHOUR INCINERATOR 

The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg 
The Temperatures of combustion: Minimum will be 850oC and max 1400oC
Post combustion: >1100oC.
The Internal diameter of the Chimney: Ø 400mm² and its height: 8 m 
The Volume of the combustion chamber: 1.200 L 
The Dimension of the door for loading in cm: 70×70. 
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. 
* A secondary injection of air to ensure perfect oxygen content. 
A control box ensuring the complete cycle of combustion. 

Fan: 
* Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle. 
Controls and regulations: 
Control box water tight to dust, including: 

* A switch circuit breaker for each engine (ventilators and burners). 
* A timer with adjustable temporization for the regulation of each burner. 
* A regulator with digital watching for the temperature of combustion. 
* A regulator with digital watching for the temperature of post combustion. 
* Electric box.

The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual batch de ashing. 
Process Filtering system: Scruber to be mentioned as optional
Emission Standards Compliance: BS 3316 or equivalent standard
Capacity to treat Plastic: Not less than 40% by weight
The supplier must give batches of spare parts of first urgency and consumable of the incinerator.
The installed incinerator must bear a one year guarantee.
The supplier shall perform an onsite installation of the incinerator.
The technical training of operators will have to be provided and given by a technician from  
the factory; it will consist of curative and preventive maintenance, and the use of machine, etc 
Fence Wire for Incinerator House (Chain Link) should be NOT less than 2.5Meters height.
Waste Storage Bay and Ash Pit drawings attached.
 
This material and equipment must include in the shed of the incinerator: foundation in rubble stone, isolation roofing against humidity; elevation with brick of 20 cm (bloc cement), continuing lintel (linteau) in reinforced concrete; steel frame (charpenteen metal); 


HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-09-17

[ecwid widgets="productbrowser search categories" default_category_id="CATEGORY_ID" default_product_id="PRODUCT_ID" lang="EN"]