HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]
Top Feeding Door HICLOVER 10-500kgs/Hr.Double Combustion Chambers Waste Incinerators
HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste.
Our products ensure efficient, clean and hassle-free disposal of medical waste is possible. The incineration of clinical waste including pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies , Drug Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste.
Items/Model |
TS100(PLC) |
TS150(PLC) |
TS300(PLC) |
TS500(PLC) |
Burn Rate (Average) |
100 kg/hour |
150 kg/hour |
300 kg/hour |
500 kg/hour |
Control Mode |
PLC Auto. |
PLC Auto. |
PLC Auto. |
PLC Auto. |
Combustion Chamber |
1200L |
1500L |
2000L |
3000L |
Internal Dimensions |
120x100x100cm |
150x100x100cm |
170x120x100cm |
210x120x120cm |
Secondary Chamber |
600L |
750L |
1000L |
1500L |
Smoke Filter Chamber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Feed Mode |
Manual |
Manual |
Manual |
Manual |
Voltage |
220V |
220V |
220V |
220V |
Power |
1.38Kw |
1.69Kw |
2.57Kw |
4.88Kw |
Diesel Oil Consumption (kg/hour) |
Ave.20.4 |
Ave.24.2 |
Ave.33 |
Ave.44 |
Natural Gas Consumption (m3n/hour) |
Ave.24.5 |
Ave.29 |
Ave.39.6 |
Ave.52.8 |
Temperature Monitor |
Yes |
Yes |
Yes |
Yes |
Temperature Protection |
Yes |
Yes |
Yes |
Yes |
Oil Tank |
200L |
300L |
500L |
500L |
Feed Door |
80x60cm |
80x60cm |
|
|
Chimney |
10Meter |
10Meter |
14Meter |
14Meter |
Chimney Type |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
1st. Chamber Temperature |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
2nd. Chamber Temperature |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
Residency Time |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
Gross Weight |
6000kg |
8500kg |
11000kg |
16000kg |
External Dimensions |
260x150x180cm |
300x160x190cm |
400x210x300cm |
450x210x300cm |
2020-09-16